GN2017
The GN2017 is an integrated highly-flexible bi-directional CDR, laser driver and limiting amplifier for 16G Fibre Channel, and FCoE SFP+ VCSEL based applications.
The GN2017 extends the reach and robustness of high-speed serial links by compensating for losses in the transmission medium and by resetting the jitter budget.
The transmit path consists of optional equalization, a multi-rate CDR and a VCSEL laser driver.
The receive path is comprised of a limiting amplifier, a multi-rate CDR, and programmable output pre-emphasis.
Both transmit and receive directions offer highly configurable eye shaping features, which allow for optimal electrical and optical outputs. Both directions also offer the option for polarity invert, loopback, output mute, and programmable output rise/fall times.
The GN2017 has an integrated analog to digital converter, which through the serial interface, provides digital diagnostic information on supply voltage, die temperature, laser bias current, and transmit optical power.
The GN2017 is configurable for multi-rate operation. Two configuration profiles optimized for different data rates can be programmed into the GN2017.
The GN2017 also offers integrated laser safety features.
The GN2017 device is packaged in a small outline 5mm × 5mm, 32-pin, high-frequency QFN package with exposed pad.
The GN2017 is Pb-free and the encapsulation compound does not contain halogenated flame retardant.
Features
- Dual CDRs with 9.95-11.3Gb/s and 14.025Gb/s reference-free operation
- Integrated limiting amplifier with sensitivity less than 10mV
- Integrated VCSEL driver
- Automatic rate detect
- On-chip Automatic Power Control (APC) loop
- Digital control and monitoring
- Integrated eye monitor
- PRBS7 generator/checker
- Bi-directional loopback
- Polarity invert, output mute available in both transmit and receive direction
- Optional transmit path input trace equalization
- Programmable analog pre-emphasis for SFI output
- Programmable VCSEL-driver Output Crossing-Point Adjust
- VCSEL driver analog pre-emphasis: programmable boost amplitude and width
- Programmable Tx Fault signalling (open-drain)
- Integrated analog to digital converter, which provides access to digital diagnostic information on supply voltage, die temperature, laser bias current, and transmit optical power
- I2C Serial Interface • Integrated laser safety features
- Single 3.3V supply (+5%/-7%)
- 5x5 32-pin QFN package
- -40°C to 95°C case operation
- Single-ended or differential, AC-coupled bias sink/source VCSEL drive operation
- Adjustable bias current from 1mA to 12mA
- Adjustable modulation current from 2mA peak-to-peak to 15mA peak-to-peak, single-ended
- Output: 2 x 50?single-ended terminations
- Crossing point adjustment (20% to 80% of eye height)
- Programmable analog pre-emphasis:
- peaking tail current range of 0 to 6mA in 32 steps
- peaking temporal range 0 to 100ps in 32 steps
- Programmable rise/fall time; 20ps to 40ps
- Optional on-chip APC loop
- Programmable Tx Fault signalling
- 4.25/8.5/14.025Gb/s Fibre Channel SFP+ VCSEL based transceivers
- 10GbE & Fibre Channel over Ethernet (FCoE) SFP+ VCSEL based transceivers
Applications
Packaging
- 32-QFN
Order Codes
- GN2017-INE3
Pb(Lead)-Free/RoHS-Green Info
(-40°C to +85°C / 4000 cycles)
(50°C, 4000 Hrs)
Explore a wealth of downloadable resources and datasheets to assist with prototyping and production.
Login or register for mySemtech to gain access to restricted product documentation and to add documents to your Watch List for update alerts
Distributor/Catalog Supplier Inventory
View product availability from participating distributors below. Browse all distributors here.
Part # | Country | Qty | Buy | Distributor |
---|
Resources
To see more videos Videos
Power, latency and cost. The three horsemen of Artificial intelligence (AI) and Machine Learning (ML) data center interconnects. Each new generation of interconnect drives a lower mW/Gbps and dollar/Gbps. Power consumption is not just about data center operating expenses. It is also about sustainability.
BLG | SIP | Optical | Revolutionizing AI and ML…
READ NOWFrom smartphones and laptops, to ATMs and online shopping, data is constantly in flight. As consumer technology and industry innovations advance, global data creation is projected to grow to 175 zettabytes (ZB) by 2025. Nearly 53ZB of that data will be consumed in real time—the data equivalent of streaming 583 billion 4K videos at once—which will strain current network infrastructure.
Tri-Edge: Preparing for Future Wireless Networks…
READ NOWOptical solutions are essential to connect and power the digital era as signal integrity forms the backbone of every digital platform. Every time someone opens a webpage or uses a connected device, data moves from point A to B—often using optical fiber. With increasing industry and consumer demand for high-quality internet and fast upload and download speeds, fiber now makes up 32% of fixed-broadband subscriptions, up 20% in the last decade. The data center and enterprise networking companies powering data usage and cloud computing need high performance optical interconnect technology to minimize cost and power consumption without sacrificing efficiency and speed.
Tri-Edge: Next-Gen Data Center and Wireless…
READ NOWBrought on by the convergence of the Cloud and the Internet of Things, hyperscale data centers and wireless operators are pushing towards 200G and 400G. Key to this transition are optical modules, which is where Semtech’s Tri-Edge™ technology plays a core role. With increasing bandwidth demands, optical modules must evolve alongside data center equipment to deliver greater density, lower power consumption, and lower latency. We spoke more about this with Timothy Vang, Vice President, Marketing and Applications at Semtech.
Tri-Edge Technology: A Q&A With Semtech
READ NOWIn the coming years, data center traffic will continue to see immense growth. Cloud services, Internet of Things (IoT) and ever-increasing broadband demand are driving a massive push by hyperscale data centers and wireless operators towards 200G and 400G. Optical modules, key building blocks for connecting data center equipment, must also evolve to meet these bandwidth demands with greater density, lower power consumption and lower latency.
Semtech’s Tri-Edge Enhances Alibaba Data Centers
READ NOWSemtech has recently returned from ECOC, one of the optical industry’s most anticipated and widely attended events of the year. The event hosts more than 6,500 scientists, researchers and industry experts from the field of high performance optical communication. Semtech’s booth was once again a hub for interested visitors eager to learn more about Semtech’s leading optical platform, and discuss current trends.
Semtech and Open Eye MSA Redefine Optical…
READ NOWThe dual-density version of the Quad Small Form-factor Pluggable (QFSP) Multi-Source Agreement (MSA) module standard looks set to be the rule for new line-cards, following a raft of demonstrations and alpha module tests in 2018. The hidden message of the QSFP-DD craze is not the physical characteristics of the module itself, but what it says about the turn to advanced signaling methods. Half a decade ago, QSFP28’s arrival heralded the coming dominance of 25Gbps electrical channels using NRZ signaling. Now, QSFP-DD, and its larger cousin, the octal SFP or OSFP, use PAM4 signaling. This most often uses 50Gbps channels, but QSFP-DD is flexible enough to use eight-channel interfaces in a variety of implementations: 25G x 8 for 200Gbit Ethernet, 50G x 8 for 400Gbit Ethernet, and perhaps some early 100G x 8 for a pre-standard 800Gbit Ethernet.
Optics MSA: QSFP-DD Puts PAM4 Signaling in…
READ NOWSlow but steady advances were made in 2018 in on-board optical links for chip-to-chip and chip-to-module interfaces. The integrated-optics revolution, anticipated three years ago when the Consortium for On-Board Optics (COBO), of which Semtech is an associate member, was launched, has been replaced by a realization that only slow migration from traditional pluggable modules will serve the data center, whether within a single line card or server blade, or between cards and racks. Even as recent as a year ago, COBO members began rethinking and changing their tune to stress coexistence of pluggable MSA modules and the embedded on-board modules chosen by COBO as a de facto standard.
A Revolution in Embedded Optics, or a Partner to…
READ NOWThe 44th installment of the European Conference on Optical Communication (ECOC) Exhibition recently concluded in Rome, Italy. At the conference, Semtech® featured several products for the critical hyper-scale data center and 5G wireless markets. The technologies demonstrated by Semtech from its diverse portfolio of Optical solutions include the ClearEdge® CDR platform for low-cost 25G SFP28 modules that will be an essential component of the 5G infrastructure build out. Additionally, Semtech demonstrated its new line of Tri-Edge CDRs and FiberEdge™ linear Physical Media Dependent (PMD) devices that will help drive current Cloud data center build outs.
5G and Data Centers: Signal Integrity Trends
READ NOW